-40%
Protection module charge pump LinuxCNC sequence switch UPDI ATTINY402 (PM21.1)
$ 4.22
- Description
- Size Guide
Description
PROTECTION MODULE - a charge pump for LinuxCNC with sequential switching and
UPDI ATTINY402
(
PM21.1)
PM21.1 module
enables power protection
(i.a. spindles, stepper motors e.t.c.) against accidental switching on.
The module also allows for a sequentially control the activation of individual power parts by limiting the current consumption, which gives you the option of using the module as a power supply switch.
OPERATING PRINCIPLE:
After appearing a 500 Hz frequency with 2% tolerance
at the IN input
, the high state will gradually appear at the 1-4 outputs by
every 5 seconds
.
After the frequency decay (e.g. disabling LinuxCNC or computer failure) all outputs will switch to low state after approx. 3 milliseconds.
The module is programmable
- if you are interested in programming other options, please contact us before ordering.
-> Programmable
ATTINY402 by UPDI interface.
LinuxCNC - CONFIGURATION EXAMPLE:
config_name.ini
..
[EMCMOT]
..
SERVO_PERIOD = 1000000
..
config_name.hal:
..
loadrt stepgen step_type=0,0
loadrt charge_pump
..
#charge pump 500Hz
addf charge-pump servo-thread
setp charge-pump.enable TRUE
net ChargePumpOut charge-pump.out => parport.0.pin-17-out
..
ADVANTAGES:
-
small size (this board is very compact, it doesn't take much space)
- milled edges (they're not sharp to the touch, it provides safety using)
- quick and easy installation
-
comfortable
mounting holes
- POLISH PRODUCTION
SPECIFICATION
Board size / holes arrangement
a multiple of 10 mm
Board dimensions
20 mm x 40 mm
Mounting holes
4 pcs., fi 3,5 mm
(for secure mounting)
Holes arrangements
10 mm x 30 mm/
Module dimensions
~
20 mm x 40 mm x 13 mm
(width x depth x height)
Power
5V
Input IN
500Hz (50% filling, 2% tolerance)
Outputs current efficiency
about 20mA (max. 25mA)
Output OUT 1
high state after 3 correct frequency cycles (1s/1000*3=3ms)
Output OUT 2
high state after 5 seconds of correct frequency
Output OUT 3
high state after 10 seconds of correct frequency
Output OUT 4
high state after 15 seconds of correct frequency
After the frequency decay for a 3 cycles (3ms) the outputs go low
.
Power signalization (POWER)
green LED
Switching signalization (ACTIVE - output OUT 1)
yellow LED
(indicates correct status)
Board type
PCB with solder mask
-------------------------------------------------------------------------------------------------------------------------------------------
NOTE:
Dear eBayers,
if You choose an ECONOMY INT'L SHIPPING option, please be aware that You decide on a UNREGISTERED form of shipping.
It means, that:
- there is no tracking number (You cannot see the status of delivery),
- we guarantee that all packages are send from us, but we cannot guarantee that Your package will be actually delivered,
- we cannot file a complaint of this fact on Post Office,
- we cannot be responsible for undelivered package.
Choosing STANDARD INT'L SHIPPING option - You can be sure, that Your package WILL BE DELIVERED for 100% !!!
Before choosing cheaper ECONOMY INT'L SHIPPING option, please rethink Your decision.
Thank You.